Probes For Coating Thickness Gauge

Probes For Coating Thickness Gauge
Product Detailed
Related Categories:Width Measuring Instruments
1.Probes for Coating Thickness Gauge 2.F1 probe 3.N1 probe 4.F400 probe 5.N400 probe

Coating Thickness Gauge

F1 probe ( Can match with MT2100,MT3100,MT4100)

F1 probe adopted magnetic method. It can measure the thickness of non-magnetic coatings ( e.g. zinc, aluminum, Cr. Copper, rubber, paint and etc.) on magnetic metallic base ( such as steel, iron, alloy and hard magnetic steel etc.)

Measuring Principles: magnetic

Measuring Range : 0-1250um

Measuring Accuracy(um) :One point calibration : ±(3%H+1)

                                        Two points calibration : ±(1%H+1)

Lower Limitation Resolution : 0.1

Minimum curvature radius (protrude) : 1.5

Minimum area diameter:φ7

Base critical thickness :0.5

F400 Probe (Can match with MT3100/4100)

F400 probe adopted magnetic method. It can measure the thickness of non-magnetic coatings ( e.g. zinc, aluminum, Cr. Copper, rubber, paint and etc.) on magnetic metallic base ( such as steel, iron, alloy and hard magnetic steel etc.)

Measuring Principles: magnetic

Measuring Range : :0-400um

Measuring Accuracy(um) :One point calibration : ±(3%H+0.7) 

                                        Two points calibration : ±(1%H+1)

Lower Limitation Resolution :0.1

Minimum curvature radius (protrude) : 1

Minimum area diameter:φ3

Base critical thickness :0.2mm

F10 Probe (Can match with MT3100/4100)

F10 probe adopted magnetic method. It can measure the thickness of non-magnetic coatings ( e.g. zinc, aluminum, Cr. Copper, rubber, paint and etc.) on magnetic metallic base ( such as steel, iron, alloy and hard magnetic steel etc.)

Measuring Principles: magnetic

Measuring Range :0- 10mm

Measuring Accuracy(um) :One point calibration : ±(3%H+10)

                                        Two points calibration : ±(1%H+10)

Lower Limitation Resolution : 1

Minimum curvature radius (protrude) : 10

Minimum area diameter:φ40

Base critical thickness : 2mm 

F1/90 Probe (Can match with MT3100/4100)

F1/90 probe adopted magnetic method. It can measure the thickness of non-magnetic coatings ( e.g. zinc, aluminum, Cr. Copper, rubber, paint and etc.) on magnetic metallic base ( such as steel, iron, alloy and hard magnetic steel etc.)

Measuring Principles: magnetic

Measuring Range : 0-1250um

Measuring Accuracy(um) :One point calibration : ±(3%H+1)

                                        Two points calibration : ±(1%H+1)

Lower Limitation Resolution :0.1

Minimum curvature radius (protrude) : Straightness

Minimum area diameter:φ7

Base critical thickness : 0.5mm

N1Probe (Can match with MT2100N/ MT3100/4100)

N1 probe adopted eddy current method. It can measure the all electrically insulating coating layers thickness (such as lacquer,Varnish, paint,anodizing) coating on non-ferrous metals (such as copper, Al, Zinc and etc) and also on austenitic VA steel materials.

Measuring Principles: Eddy current method

Measuring Range : 0-1250um

Measuring Accuracy(um) :One point calibration :  ±(3%H+1.5)

                                        Two points calibration : ±(1%H+1.5)

Lower Limitation Resolution :0.1

Minimum curvature radius (protrude) :3

Minimum area diameter:φ5

Base critical thickness : 0.3mm 

N400 Probe (Can match with MT3100/4100)

  N400 probe adopted eddy current method. It can measure the all electrically insulating coating layers thickness (such as lacquer,Varnish, paint,anodizing) coating on non-ferrous metals (such as copper, Al, Zinc and etc) and also on austenitic VA steel materials.

Measuring Principles: Eddy current method

Measuring Range : 0-400um

Measuring Accuracy(um) :One point calibration :  ±(3%H+1)

                                        Two points calibration : ±(1%H+1)

Lower Limitation Resolution :0.1

Minimum curvature radius (protrude) :1.5

Minimum area diameter:φ4

Base critical thickness : 0.3mm 

Probes For Coating Thickness Gauge